Equipment at NIC@HU

[Microscope room]
*Station-1:Spectral Confocal Microscopy
*Station-2:Total Internal Reflection Fluorescence Microscopy
*Station-3:Multi Fluorescence Time-lapse Microscopy
*Station-4:Realtime Confocal Microscopy
*Station-5:Multi Point Scanning Two Photon Excitation Microscopy

* Click below station name for more information.


Station-1 Station-2 Station-3 Station-4 Station-5

Station1  Spectral Confocal Microscopy

  • Inverted Microscopy Ti-E (Nikon)
    with Motorized XY-Stage and Perfect Focus System (Nikon)
  • Spectral Confocal Microscopy System A1R (Nikon)
  • Stage Incubation System INUBG2H-TIZB (Tokai HIT)

Station2  Total Internal Reflection(TIRF) Microscopy

  • Inverted Microscopy TE2000-E(Nikon)
  • Laser TIRF Illuminator System (Nikon)
  • EM-CCD Camera Rolera EM-C 2(Qimaging, Nippon Roper)
  • MetaMorph/MetaFluor Analysis Software (Molecular Devices)
  • Stage Incubation System INUG2-ONII (Tokai HIT)
  • Vibration Isolation System (supplied by Systembrain)

Station3  Multi-Fluorescence Time-lapse Microscopy

  • Inverted Microscopy Ti-E (Nikon)
      with Perfect Focus System (Nikon)
  • Cooling type CCD Camera ORCA-R2 (Hamamatsu Photonics)
  • High-definition color CCD camera DS-Fi2 (Nikon)
  • MetaMorph Analysis Software (Molecular Devices Japan)
  • AquaCosmos Analysis Software (Hamamatsu Photonics)
  • Motorized XY-Stage System MSS-BT110 (Chuo Precision Industrial)
  • Stage Incubation System INUBG2TF-WSKM (Tokai HIT)
  • Vibration Isolation System (supplied by Systembrain)

Station4  Realtime Confocal Microscopy

  • Confocal System Unit with Nipkow desk CSU10 (Yokogawa)
  • Inverted Microscopy Ti-E (Nikon)
      with Perfect Focus System (Nikon)
  • Cooling type CCD Camera ImagEM C9100-13 (Electron Multiplier CCD)
          (Hamamatsu Photonics)
  • AquaCosmos Analysis Software (Hamamatsu Photonics)
  • Stage Incubation System INUG2-TIZB (Tokai HIT)
  • Vibration Isolation System (supplied by Systembrain)

Station5  Multi Point Scanning Two Photon Excitation Microscopy

  • Confocal System Unit with Nipkow desk CSU-X1 (Yokogawa)
  • Inverted Microscopy ----
  • Camera EM-CCD:EM-C 2 and CMOS:OptiMOS (Qimaging, Nippon-Roper)
  • Stage Incubation System INUG2-ONI (Tokai HIT)


JASCO: Automatic Fluorescence Polarimeter FP-715

Tokai Hit:
  Tube heater MATS-TH
  Stage automatic thermo control system MATS-505R30
  Digital Thermometer with super fine sensor probe TSU-0125
Hamamatsu Photonics:
  W-View Gemini: Image Splitting Optics A12801-01
  Flow chamber A8819(Open PDF file)
ATTO:
  Precision Perista Bio Mini Pump AC-2110

* Following links will open as PDF's in a new window

2017.03.01. UPDATE!
Filter blocks list (240kB)
Objectives list (96kB)

[Data room]
  Hamamatsu Photonics: AquaCosmos Analysis Software
  Molecular Devices: MetaMorph Analysis Software
  Nippon Roper: ImagePro Plus
  Solution Systems: Huygens, Deconvolution software
    * Solution Systems is a agent of Huygens in Japan.
  PrizMage, Fluorescence unmix software

[Culture room]
  Inverted Phase Contrast Microscopy TE300 (Nikon)
  CO2Incubator (espec)
  Clean bench (AIRTECH)